The term Effective Radiated Power or ERP appears frequently in ham discussions, antenna literature and regulatory documents. Continue reading Effective Radiated Power (ERP)
Category: Amateur Radio
BN43-2402 balun example
An online poster recently sought to design a broadband 9:1 transformer for HF.
Choosing a BN43-2402 balun core, he planned to use a 2t primary and 6t secondary for a nominal 50Ω input. He subsequently posted measurements of the prototype.
What might we expect… is it a good starting point.
A first approximation at the low frequency end with a medium µ core is that it is like an ideal transformer withe the magnetising impedance in shunt with the primary. Continue reading BN43-2402 balun example
OCF short vertical dipole for HF
The OCF short vertical dipole for HF has become popular, particularly disguised as a flag pole for low impact installations and encouraged by claims of outstanding performance. The antenna was described in QST and a commercial version was available at time of writing.
The rationale for the design is that it is a short dipole, not requiring radials, and feed point offset downwards by 30% as an optimal value for performance (driven by often unsound assessments of coax loss).
Claims include:
Off-Center Fed Vertical Dipole design means no radials, 90% efficient or better across 80m – 10m
Above is the promising gain plot for one of the commercial implementations, it is only one S point (6dB) behind a quarter wave vertical with 4 buried radials. Continue reading OCF short vertical dipole for HF
MFJ-993B internal balun review
The MFJ-993B auto antenna tuner includes an internal balun, this article is a review of that balun.
The schematic shows the balun as a Guanella 4:1 balun with the usual external link to one of the coaxial antenna sockets. (The label “Z balanced” is misleading, clearly one of the terminals is grounded and this is the unbalanced connection to the coax connector via a link. The antenna connects to the left hand terminals.)
Unlike almost all ATUs with an internal balun, this is a current balun (to their credit), but a 4:1 balun.
There are two aspects of balun behaviour that are of particular interest:
- choking or common mode impedance; and
- impedance transformation.
Shack entry / ATU configuration for my G5RV with tuned feeder
At MFJ-993B on my G5RV with tuned feeder I discussed first impressions of the replacement ATU.
This article documents the physical layout.
The antenna is a G5RV with tuned feeders (Varney 1958). The tuned feeder is home made two wire line using 2mm diameter copper spaced 50mm.
Above at the right, the open wire line terminates on a home made balun on the feed line entrance panel, see
Design / build project: Guanella 1:1 ‘tuner balun for HF’ – #4 for details of the balun. This is all under the building eaves, but it is waterproof… the area is regularly jetted with high pressure water to clean insects away. Continue reading Shack entry / ATU configuration for my G5RV with tuned feeder
Cheap Chinese compression connector tool
I was given one of these cheap Chinese compression connector tool because “it didn’t work any good”. Continue reading Cheap Chinese compression connector tool
Zo of two wire line
I saw a recent discussion where the blind were leading the blind on the dimensions of a twisted two wire line for Zo=50Ω for use in a balun.
The poster had used an online calculator which used the well known log function for estimating Zo of an air spaced two wire line… the calculator, like most quotations of the formula do not state clearly that it is only an approximation of limited validity, and the calculator returned results for ridiculous inputs (like negative spacing).
The graph above (Duffy 2008) shows the log approximation, and the underlying acosh based estimate. I say estimate because the acosh function does not account for proximity effect which becomes significant at the very closest spacings, and internal inductance which becomes significant at lower frequencies. Proximity effect depends on more than just the spacing/diameter ratio and so cannot be shown on the above graph.
So how did our poster find dimensions for wires for Zo=50Ω when the log graph above shows that as the wire centre to centre spacing approaches the wire diameter, it the wires approach touching, Zo approaches 83Ω? Continue reading Zo of two wire line
The sign of Return Loss
I was browsing a ham forum recently when I came across a Return Loss plot apparently from a ham grade miniVNA Tiny.
Lets just remind ourselves of the meaning of the term Return Loss. (IEEE 1988) defines Return Loss as:
(1) (data transmission) (A) At a discontinuity in a transmission system the difference between the power incident upon the discontinuity. (B) The ratio in decibels of the power incident upon the discontinuity to the power reflected from the discontinuity. Note: This ratio is also the square of the reciprocal to the magnitude of the reflection coefficient. (C) More broadly, the return loss is a measure of the dissimilarity between two impedances, being equal to the number of decibels that corresponds to the scalar value of the reciprocal of the reflection coefficient, and hence being expressed by the following formula:
20*log10|(Z1+Z2)/(Z1-Z2)| decibel
where Z1 and Z2 = the two impedances.
(2) (or gain) (waveguide). The ratio of incident to reflected power at a reference plane of a network.
Return Loss expressed in dB wrt a real reference impedance will ALWAYS be a positive number in passive networks.
Return Loss according to the miniVNA Tiny
Above, the miniVNA Tiny presents Return Loss as a negative value. Continue reading The sign of Return Loss
Is the premises main earthing conductor ok as a lightning down conductor
Upon reading Rationale for sizing of lightning down conductor a correspondent asks whether his premises 4mm^2 main earthing conductor ok as a lightning down conductor.
Intended purpose of electrical installation ground electrode
The usual source of current on the premises main earth conductor would be a fault energised by the incoming supply. To understand the implications, lets review the supply system. Continue reading Is the premises main earthing conductor ok as a lightning down conductor