Graphic demonstration of loss under standing waves #3

Having recently published Graphic demonstration of loss under standing waves, I have received a stream of emails asking whether some online calculator or another is subject to the errors discussed in the article.

Clip 080If we look at the graph from the article showing the example of a load of 500+j0Ω on 5m of RG58A/U, test the left hand data point at 1MHz and see what you get. If the loss is greater than the matched line loss (around 0.08dB), the calculator probably uses one of the flawed formulas discussed in the article… in any event it is wrong.

Here is an example from KV5R.com.

Screenshot - 22_01_16 , 10_11_37

The calculated loss is around 4 times what it should be. Continue reading Graphic demonstration of loss under standing waves #3

VSWR expressed as 1:n

At Expression of VSWR as a simple decimal real number I put the case for expressing VSWR simply as a real (ie a decimal) number rather than in the ratio form.

Lets remind ourselves of the meaning of VSWR (SWR).

(Terman 1955) gives a meaning for the term SWR (or VSWR).

The character of the voltage (or current) distribution on a transmission line can be conveniently described in terms of the ratio of the maximum amplitude to minimum amplitude possessed by the distribution. This quantity is termed the standing wave ratio (often abbreviated SWR)…

Standing-wave ratio=S=Emax/Emin

Terman has not dealt with the complication of short lines and lossy lines.

Note that the use of capital E implies the magnitude of voltage, so Emax/Emin must always be a positive number greater than or equal to 1.0 under that definition. Under that definition (and it has shortcomings), VSWR expressed as a ratio of m:n (and n is usually 1), m MUST be equal to or greater than n.

Screenshot - 20_01_16 , 11_35_41

Above is an extract from the brochure for Icom’s newest offering, the IC-7300. Continue reading VSWR expressed as 1:n

Exploiting your antenna analyser #11

Backing out transmission line

Often we make measurements through a section of transmission line, and the measurements are wrt the reference plane, which for many analysers is the connector on the instrument.

Some analysers, or their associated software allow the effects of the transmission line to be backed out.

Screenshot - 17_01_16 , 09_16_18

Above is a Smith chart view of measurement of a test antenna through some length of RG58. The antenna will have R<50Ω at minimum VSWR, so the angle of the complex reflection coefficient Γ will be close to 180° at the feed point. Antscope uses a different notation, but shows here the angle at the point of measurement to be -15.1°, so we need to increase it by 180–15.1=195.1°, which will take about half that electrical length of line, 97.6°. From TLLC, I calculate the length involved is 7.6m of RG58, which is an estimate that gives a starting point for backing out the cable. Continue reading Exploiting your antenna analyser #11

Some thoughts on noise on 6m (50MHz)…

External noise

External noise is the noise external to the receiver system.

(ITU-R 2015) gives some guidance on expected ambient noise.

Screenshot - 10_01_16 , 09_49_56

Above is Figure 10 which gives guidance on the expected median ambient noise figure.

Screenshot - 16_01_16 , 11_12_29

The table above gives calculates noise power in a 2kHz bandwidth receiver with lossless antenna system for the lower ham bands from the equations given in (ITU-R 2015). Note that the medians vary somewhat with location and time, see (ITU-R 2015).

From the table, business (city) man made noise (A) is 17dB higher than galactic (E), and rural (C) is 7dB higher than galactic. Unless there is some ionospheric absorption occurring, you are unlikely to observe noise below galactic level.

Noise can be expected to vary by hour of day, from day to day, and season to season. Importantly, noise may vary with direction, eg pointing through busy roads, office buildings, shopping centres etc, neighbouring buildings, powerlines etc.

Measurement of external noise is not too difficult, but rarely do hams understand quantitatively their own noise environment.

Internal noise

Noise contributed by the various stages of a receiver system can be reduced to an equivalent input noise at the input of a noiseless receiver, and that is often expressed in the form of the receiver Noise Figure.

A typical receiving system for 6m would have a noise figure around 6dB (at the antenna connector). As will be seen, there is little need for better noise figure.

The noise floor of a receiving system with NF=6dB (4.5dB receiver and 1.5dB line loss) is -135dBm. In such a receiver, AGC action is typically delayed until the signal is around 25dB above the noise floor, around -110dBm in this case. There will be no S meter deflection in traditional receivers below AGC onset.

Clip 107

Above, the median expected noise falls below the typical AGC threshold (S meter threshold) for the example receiver (-110dBm), and apart from Curve A, the noise may not cause S meter deflection.

In a single isolated measurement at my location, I measured -123dBm which is in the range expected of a semi rural residential with underground power.

Receivers with an additional preamp may show significant S meter deflection, the preamp will increase gain without significantly improving S/N ratio, indeed they may degrade S/N ratio.

Total noise power

The internal and external noise power add, but it is the power in watts or in equivalent temperature that can be added, not the dBm figure.

Clip 105

The chart above shows the effect of combining two additive power values. If they differ by more than 20dB, the sum is within 0.05dB of the higher power. For lesser ratios, the weaker power needs to be factored in, and the graph provides a simple means if you don’t want to crunch the numbers.

For example, if we took the median power in a quiet rural precinct from the table above to be -119.9dBm, and noise floor to be -135dBm, looking up -135–119.9=-15.1dB on the horizontal axis we see that the combined power is 0.15dB more than the higher power, so -119.1+0.15=-119.8dBm. This is unlikely to cause S meter deflection most of the time as the median is almost 10dB lower than AGC onset.

Working the numbers for residential precinct from the table above to be -114.6dBm, and noise floor to be -135dBm, looking up -135–114.6=-20.4dB on the horizontal axis we see that the combined power is 0.05dB more than the higher power, so -114.6+0.05=-119.8dBm., -114.6. This is likely to cause S meter deflection occasionally as the median is just 5dB lower than AGC onset.

Low noise antennas

One of the recent market directions is so-called low noise antennas. The term is used to describe directional antennas with reduced side lobe response inspired perhaps by (Bertelsmeier 1987) who contrived a rather naive statistic based on the noise power captured by a Yagi in free space tilted up 30° from the Z=0 plane and excited by two arbitrary noise scenarios in the upper and lower hemispheres, the statistic labelled G/Ta, transformed by others to G/T in  ignorance of the true meaning of the industry term G/T.

Reduced side lobe response sounds a good idea, but what is the expected impact on total external noise power received?

For a Yagi in free space, if the distribution of external noise is uniform in three dimensional space:

  • the same noise power will be received irrespective of the pointing of the antenna; and
  • a lossless antenna captures the same amount of noise power irrespective of its gain.

But we are not in free space, are we.

For Yagi pointing horizontally over flat ground, if the distribution of external noise is evenly distributed over all azimuth headings:

  • the same noise power will be received irrespective of the pointing of the antenna; and
  • a lossless antenna captures the same amount of noise power irrespective of its gain.

The situation changes if the noise intensity is not uniform with azimuth bearing and elevation if there are more concentrated noise sources.

It should be apparent that reducing the average gain off the main lobe reduces power from noise sources to the side and rear, but if the pattern is not even, and it never is, then it is a matter of chance as to whether pattern nulls or peaks coincide with concentrated noise sources when pointing in a desired direction.

The complexity of this environment mitigates against a meaningful single metric for the noise capture of a Yagi.

One cannot argue against the logic that reduced sidelobe gain is an advantage in reducing off boresight noise, but it does imply increased main lobe gain (and possibly noise pickup) the question is really how much net advantage there is on 50MHz in your station with your noise environment on the paths you see as high priority.

References

  • Bertelsmeier, R. 1987. Equivalent noise temperatures of 4-Yagi-arrays for 432MHz. DUBUS.
  • Duffy, O. May 2013. Noise and receivers presentation. https://owenduffy.net/files/NoiseAndReceivers.pdf.
  • ITU-R. 2000. Recommendation ITU-R S.733-2 (2000) Determination of the G/T ratio for earth stations operating in the fixed-satellite service .
  • ITU-R. Jul 2015. Recommendation ITU-R P.372-12 (7/2015) Radio noise.

ANS T1.523-2001, Telecom Glossary 2000 and Return Loss

A correspondent has suggested to me that my practice of giving Return Loss as a positive dB value is wrong, citing US FS-1037C.

US FS-1037C has been superseded by ANS T1.523-2001, Telecom Glossary 2000, and the wording in the latter is identical to the former, so let’s discuss the more current document. Continue reading ANS T1.523-2001, Telecom Glossary 2000 and Return Loss

On negative VSWR

(Terman 1955) gives a meaning for the term SWR (or VSWR).

The character of the voltage (or current) distribution on a transmission line can be conveniently described in terms of the ratio of the maximum amplitude to minimum amplitude possessed by the distribution. This quantity is termed the standing wave ratio (often abbreviated SWR)…

Standing-wave ratio=S=Emax/Emin

Note that the use of capital E implies the magnitude of voltage, so Emax/Emin must always be a positive number.

Lossless line example

Let’s look at an example of a 5Ω load on a line with Zo=50+j0Ω at 0.1MHz.

Clip 087

The standing wave is observable, the expression VSWR=Emax/Emin seems straight forward enough. The voltage along the line could be sampled and VSWR determined, seems all very practical. Continue reading On negative VSWR

NEC model of the quarter size G5RV

Fractional G5RV antennas seem very popular in the US market, and they appeal to hams wanting multi band performance in small space.

One of the offerings is the quarter size G5RV, commonly marketed as the G5RV Mini.

The original concept set out by G5RV was a combination of a centre fed dipole and open wire transformation section to successfully deliver a lowish VSWR50 on several of the pre-WARC bands. This enabled arbitrary length low Z feed extension to the transmitter, and allowed direct attachment to transmitters of the common design of the day (1950s). Continue reading NEC model of the quarter size G5RV

Is maximum power transfer and conjugate matching simultaneously possible

A reader has asked the question in a transmission line context after reading Walter Maxwell’s teachings on system wide conjugate matching.

In the real world, transmission lines have loss and almost always, the nature of that loss will mean that Zo is not purely real.

The answer to the question depends on whether or not there are standing waves on the transmission line.

Nothing in this article is to imply that a transmitter is well represented by a Thevenin equivalent source. Continue reading Is maximum power transfer and conjugate matching simultaneously possible

Exploiting your antenna analyser #10

Measuring an RF inductor

This article walks through practical measurement of a ferrite toroidal inductor using an antenna analyser.

To be relevant practically, lets use an example from N4SPP’s end fed wire antenna on 3.6MHz. His coupling transformer uses a two turn winding on an FT240-43 core for the nominal 50Ω connection to the antenna system.

We could calculate the impedance of this winding using one of the plethora of online and desktop inductance calculators, but lets first fetch the data from the manufacturer.

Screenshot - 29_12_2015 , 11_05_50 AM

A simple statistic that is widely used is Al, and above, Fair-rite gives Al=1075nH +/-20%. Note that although they give a tolerance of +/-20%, it is not uncommon that manufactured product has greater error, they may have optimistically quoted the standard deviation and it is easy to fall outside that (37% chance). Continue reading Exploiting your antenna analyser #10