Rigexpert Antscope v4.3.1 released

It seems yet another new version of Rigexpert Antscope has been released, and it maintains the scale limits available for R,X plots to +/-2000Ω, it still does not allow the range permitted by v4.2.57 (+/-5000Ω).

No change details provided by Rigexpert.

Back to v4.2.57, though it is very likely it has undisclosed defects fixed in later releases.

Bottom line is that if you want an analyser with direct graphing of impedances over 2000Ω (eg measuring common mode choke impedance), think of a different analyser.

 

Ten-tec on the meaning of SWR

In a recent long running thread on impedance matching on one of the online fora, one poster offered the Ten-tec 540 manual as a reference for clarity on the subject (which of course got murkier with every posting as contributors added their version to the discussion).

The Ten-tec 540 was made in the late 1970s, one of the early radios with a solid state PA, and their manual give the Technical facts of life to guide new owners to successful exploitation of this new technology.

Amongst the technical facts of life is this little gem:

The standing wave ratio is a direct measure of the ratio between two impedances, ie an SWR of 3 to 1 tells us that one impedance is three times the other. Therefore the unknown impedance can be three times as large or three times as small as the known one. If the desired impedance that the transceiver wants to see is 50 ohms, and SWR of 3 to 1 on the line may mean a load impedance of either 150 or 17 ohms. …

This says that the SWR wrt 50Ω implies just two possible impedances, he is very wrong… it implies an infinite set of possible impedances. Continue reading Ten-tec on the meaning of SWR

Reflected power alarm for the MFJ-993B

This article describes an add-on to a MFJ-993B auto ATU to provide an audible alarm when reflected power exceeds a set threshold. A deficiency of the original design IMHO.

The solution uses the generic heating / cooling controller (hcctl) configured for its alarm function only, including a function to silence the alarm.

screenshot-03_12_16-18_34_50Above is the directional coupler part of the MFJ-993B. The REF test point is designed to present voltages within the range 0-5V when used within the stated power ratings. Continue reading Reflected power alarm for the MFJ-993B

Radio-Kits SWR meter – build and review

This article describes my build of a Radio-Kits SWR meter (v1.1) and post implementation review.

Advertised features:

  • HF coverage – 1.8-30MHz
  • Displays VSWR, forward power, reverse power and supply voltage
  • Peak reading power meter
  • Bar graph or numerical format
  • Reverse power alarm with adjustable threshold
  • Auto turn on in presence of RF – sensitivity about 1 watt
  • Optional turn off after preset time – 10-240 seconds
  • Backlit LCD display with variable brightness
  • Reverse polarity protection

I purchased the kit some years ago, and on receiving it and reviewing the circuit I formed the view that it was likely to have unacceptable Insertion VSWR on 1.8Mhz, and probably 3.5MHz bands… so I lost interest in assembling the kit. However, I have belatedly constructed the kit, calibrated and tested it.

Implementation

The kit is supplied as a PCB and parts, no casework is supplied.

The board was difficult to solder, the strain relieved ground plane connections of components have very little donut to contact for heat transfer and are much harder to solder than the other pads. The strain relief is a dubious feature that makes soldering difficult.

rkswr01

Above, the kit assembled in a die-cast aluminium box. An opening for the LCD was milled into the box, and holes drilled for the rest of the fit up. The kit does not lend itself to this boxing as the buttons out the top and display out the front are a problem to fit up. A poor mechanical design.

rkswr02

Above is the interior of the box showing the LCD display and the external BNC connectors fitted (substituted for the ubiquitous UHF connectors supplied with the kit). Continue reading Radio-Kits SWR meter – build and review

Grebenkember’s original Tandem match

(Grebenkemper 1987) describes a directional coupler that has become very popular, especially in commercial implementation.

screenshot-22_11_16-07_23_25The simplified circuit above from Grebenkemper’s article illustrates the key elements of the directional coupler.

An important detail of the design is that the primary of the right hand transformer appears in shunt with the antenna load, and the magnetising impedance of that transformer core compromises Insertion VSWR. It is important that the magnetising impedance is sufficiently high (or the admittance sufficiently low) to not cause significant Insertion VSWR.
Continue reading Grebenkember’s original Tandem match

KitsAndParts.com QRP SWR bridge

The project is to build a test a couple of QRP VSWR detectors by KitsAndParts.com (http://www.kitsandparts.com/bridge.php) rated at 10W.

kitsandparts002

Above are the completed kits.

bridge_sch

Above is the schematic. The bridge uses a type of Sontheimer coupler (Sontheimer 1966) and these are commonly poorly designed. The first question is whether the magnetising impedance of T2 which appears in shunt with the load is sufficiently high to not give rise to poor insertion VSWR. Continue reading KitsAndParts.com QRP SWR bridge

Walter Maxwell’s teachings on system wide conjugate matching

Walt Maxwell (W2DU) made much of conjugate matching in antenna systems, he wrote of his volume in the preface to (Maxwell 2001 24.5):

It explains in great detail how the antenna tuner at the input terminals of the feed line provides a conjugate match at the antenna terminals, and tunes a non-resonant antenna to resonance while also providing an impedance match for the output of the transceiver.

Walt Maxwell made much of conjugate matching, and wrote often of it as though at some optimal adjustment of an ATU there was a system wide state of conjugate match conferred, that at each and every point in an antenna system the impedance looking towards the source was the conjugate of the impedance looking towards the load.

This is popularly held to be some nirvana, a heavenly state where transmitters are “happy” and all is good. Happiness of transmitters is often given in online discussion by hams as the raison d’être for ATUs . Continue reading Walter Maxwell’s teachings on system wide conjugate matching

Zo of two wire line

I saw a recent discussion where the blind were leading the blind on the dimensions of a twisted two wire line for Zo=50Ω for use in a balun.

The poster had used an online calculator which used the well known log function for estimating Zo of an air spaced two wire line… the calculator, like most quotations of the formula do not state clearly that it is only an approximation of limited validity, and the calculator returned results for ridiculous inputs (like negative spacing).

clip-221

The graph above (Duffy 2008) shows the log approximation, and the underlying acosh based estimate. I say estimate because the acosh function does not account for proximity effect which becomes significant at the very closest spacings, and internal inductance which becomes significant at lower frequencies. Proximity effect depends on more than just the spacing/diameter ratio and so cannot be shown on the above graph.

So how did our poster find dimensions for wires for Zo=50Ω when the log graph above shows that as the wire centre to centre spacing approaches the wire diameter, it the wires approach touching, Zo approaches 83Ω? Continue reading Zo of two wire line