A simple Simsmith model for exploration of a common EFHW transformer design – 2t:14t

This article describes a Simsmith model for an EFHW transformer using a popular design as an example.

This article models the transformer on a nominal load, being \(Z_l=n^ 2 50 \;Ω\). Real EFHW antennas operated at their fundamental resonance and harmonics are not that simple, so keep in mind that this level of design is but a pre-cursor to building a prototype and measurement and tuning with a real antenna.

Above is the prototype transformer measured using a nanoVNA, the measurement is of the inductance at the primary terminals with the secondary short circuited.

The prototype transformer follows the very popular design of a 2:14 turns transformer with the 2t primary twisted over the lowest 2t of the secondary, and the winding distributed in the Reisert style cross over configuration.

The winding layout used in the prototype is that recommended at 10/(15)/20/40 Mini End fed antenna kit, 100 Watt 1:49 impedance transformer .

Above is a plot of the equivalent series primary inductance of the prototype transformer with short circuit secondary calculated from s11 measured with a nanoVNA from 1-31MHz. Note that the inductance is fairly independent of frequency, rising a little at the high frequency end probably due to effects of distributed capacitance and self resonance. This suggests that leakage flux is for the most part not immersed in the ferrite core, and it provides hints as to how to minimise it.

Note that since the inductance of the primary and secondary are frequency dependent (by virtue of the ferrite characteristic), and that leakage inductance is relatively independent of frequency (see above), that the flux coupling coefficient k is frequency dependent, and making it constant is not a very good model at these frequencies.

It might appear that k is fairly independent of freq, but 1-k is not, and it is 1-k that is used to evaluate leakage inductance in the k based approach, so it delivers a poor estimate of leakage inductance when the magnetising inductance is frequency dependent (as it is likely to be with ferrite).

It can be seen above that 1-k varies over a 2:1 range in this model, which would drive a 2:1 variation in leakage inductance… when leakage inductance is almost constant (see the earlier chart).

Above is the equivalent circuit used to model the transformer. The transformer is replaced with an ideal 1:n transformer, and all secondary side values are referred to the primary side.

  1. Secondary side leakage inductance Lls is divided by n^2 to obtain the value primary referred leakage inductance in the circuit diagram.
  2. Cse is an equivalent shunt capacitance to partially model self resonance effects.
  3. Bm is the magnetising susceptance (calculated from other parameters).
  4. Gm is the magnetising conductance (calculated from other parameters).
  5. Llp is the primary side leakage inductance.
  6. Ccomp is a compensation capacitance.

A Simsmith model was built to implement the transformer model above.

  1. Complex core permeability is captured from a permeability data file.
  2. np is the number of turns on the primary.
  3. ratio is the turns ratio.
  4. cores is the number of cores in a stack.
  5. cse is Cse per the circuit diagram.
  6. Ll is the value of Llp and Lls’ (which are assumed equal).

Having measured the short circuit input inductance to be 360nH, it is distributed equally over Llp and Lls’ so Ll is entered as 180nH.

Above is a screenshot of the Simsmith model. Block D1 is used for data entry to supply some values direct and calculated to the following blocks.

Tfmr is the model of the transformer as shown in the diagram earlier.

Above is the modelled VSWR response of the compensated transformer on a nominal load. It is not brilliant, but might be acceptable to many users.

Above, drilling down on more detail, the \(Loss=10 log \frac{PowerIn}{PowerOut}\) curve is troubling. 1dB loss @ 7.0MHz means that only 74% of the transformer input power power reaches the transformer output terminals, the deficit being lost mostly in heating the ferrite core. Of course you transmitter might not develop its rated power into the load that it sees, there could be a further reduction in power output.

So despite its popularity, this is an appalling design. It has high loss due to insufficient turns, and high leakage inductance due to winding layout and high turns. Acceptable designs are a compromise between bandwidth and loss for a give core, and small is beautiful from the transmission parameters, but not for power handling.

Try changing model parameters in the sample model (link below), change mix type, measure the leakage inductance for some different winding configurations and use it.

The model input value aol is the core geometry ΣA/l (m) and can be calculated from dimensions using Calculate ferrite cored inductor – rectangular cross section. Some datasheets give ΣA/l or ΣA/l in various units which can be inverted / scaled as necessary. Calculate ferrite cored inductor (from Al) can calculate ΣA/l (m) from Al.

The model does not give a definitive design, but it does help to explore the effects of magnetising admittance and leakage inductance on VSWR bandwidth, loss etc.

References

Sample Simsmith model for download: EFHW-5943003801-43-2020-2-14xk.7z . (Compressed with 7zip.)