RTKLIB using stunnel for TLS connection to NTRIP host

RTKLIB does not currently natively support TLS, hopefully it will in time.

This article details configuration of RTKLIB rtknavi to work on a Win10 workstation using stunnel to connect to a NTRIP server that is only available using TLS.

The version of rtklib used is v2.4.3b33, and stunnel v5.60.

Continue reading RTKLIB using stunnel for TLS connection to NTRIP host

nanoVNA – measure common mode choke – it is not all that hard!

It seems that lots of hams find measuring the impedance of a common mode choke a challenge… perhaps a result of online expert’s guidance?

The example for explanation is a common and inexpensive 5943003801 (FT240-43) ferrite core.

Expectation

It helps to understand what we expect to measure.

See A method for estimating the impedance of a ferrite cored toroidal inductor at RF for an explanation.

Note that the model used is not suitable for cores of material and dimensions such that they exhibit dimensional resonance at the frequencies of interest.

Be aware that the tolerances of ferrite cores are quite wide, and characteristics are temperature sensitive, so we must not expect precision results.

Above is a plot of the uncalibrated model of the expected inductor characteristic, it shows the type of response that is to be measured. The inductor is 11t wound on a Fair-rite 5943003801 (FT240-43) core in Reisert cross over style using 0.5mm insulated copper wire. Continue reading nanoVNA – measure common mode choke – it is not all that hard!

Chinese batteries – replacements for Makita 1220 battery pack

Buying Chinese batteries is a minefield. Experience has been that they rarely meet specified capacity, and less that 10% of specified capacity is not that unusual.

So, with that background I searched eBay for replacement batteries for a Makita drill / driver. The current pair of batteries are Chinese source, purchased about 5 years ago, label rating is 2.0Ah, and measured capacity now is 1.3-1.4Ah… which is not too bad, they were 1.7-1.8Ah when new (yes, below spec).

There were very many sellers selling a lot of two packs rated at 3.6Ah for around $34 including delivery. That is very cheap, too good to believe? Let’s rely on eBay Buyer Protection to put them to the test.

The two batteries arrived quickly and were put through charge / discharge cycles to condition them.

Above are the C/5 discharge curves for both batteries on the third cycle, capacity is 1.3Ah, just 36% of the label rating. Continue reading Chinese batteries – replacements for Makita 1220 battery pack

Loop in ground (LiG) – #10 – implementation – earthworks

The Loop in Ground project is about a receive only antenna for low HF, but usable from MF to HF. The objective is an antenna that has low Signal to Noise Degradation (SND), and low noise pickup by virtue of some separation of near field radiators.

The antenna comprises a square loop of 3m sides of 2mm bare copper wire, buried 20mm in the soil.

Above is the site marked out for earthworks, but excavation of a narrow slot 25mm deep. On the far side of the loop is an already installed plastic irrigation valve box for the transformer. Continue reading Loop in ground (LiG) – #10 – implementation – earthworks

A simple Simsmith model for exploration of a 50Ω:200Ω transformer using a 2843009902 (BN43-7051) binocular ferrite core

EFHW-2843009902-43-2020-3-6kThis article applies the Simsmith model described at A simple Simsmith model for exploration of a common EFHW transformer design – 2t:14t to a ferrite cored 50Ω:200Ω transformer.

This article models the transformer on a nominal load, being \(Z_l=n^ 2 50 \;Ω\). Keep in mind that common applications of a 50Ω:200Ω transformer are not to 200Ω transformer loads, often antennas where the feed point impedance might vary quite widely, and performance of the transformer is quite sensitive to load impedance. The transformer is discussed here in a 50Ω:200Ω context.

Above is the prototype transformer using a 2843009902 (BN43-7051) binocular #43 ferrite core, the output terminals are shorted here, and total leakage inductance measured from one twisted connection to the other. Continue reading A simple Simsmith model for exploration of a 50Ω:200Ω transformer using a 2843009902 (BN43-7051) binocular ferrite core

A simple Simsmith model for exploration of a common EFHW transformer design – 2t:14t

This article describes a Simsmith model for an EFHW transformer using a popular design as an example.

This article models the transformer on a nominal load, being \(Z_l=n^ 2 50 \;Ω\). Real EFHW antennas operated at their fundamental resonance and harmonics are not that simple, so keep in mind that this level of design is but a pre-cursor to building a prototype and measurement and tuning with a real antenna.

Above is the prototype transformer measured using a nanoVNA, the measurement is of the inductance at the primary terminals with the secondary short circuited. Continue reading A simple Simsmith model for exploration of a common EFHW transformer design – 2t:14t