On testing two wire line loss with an analyser / VNA – part 3 showed how to estimate two wire line characteristics from dimensions and an estimate of velocity factor. This article does the same for a coax example
To take an example, let’s use one posted online recently:
Stranded Tinned copper center conductor, 0.037″ od Solid, white dielectric (not foamed), 0.113″ od Od of jacket, 0.196″
The dimensions we are interested in are OD of dielectric, 2.97mm (0.113″) and OD of the inner conductor, 0.989mm (0.037″). A solid white dielectric (as opposed to translucent) is likely to be PTFE which has a velocity factor around 0.7 (in most PTFE cables) and we will assume a loss tangent of 1e-4 (typical of non-polar polymers). Continue reading Estimating characteristics of a sample of coax from dimensions and properties