OwenDuffy.net 


Estimate Matched Line Loss from paired VSWR measurements

This calculator allows estimation of Matched Line Loss from paired VSWR measurements as discussed by (Witt 2005).

Extending Witt's calculation, this calculator requires specification of the VSWR at the loads, allowing reduction of error in the result due to innaccuracy of the two loads used.

The results are valid only for linear circuits.

Inputs:
    Load 1 Load 2
VSWR at load:  
VSWR at source:  
Results:  
Matched Line Loss (dB)    

The calculator does not do a lot of error checking, if you enter nonsense, it will probably produce nonsense.

References

Changes

Version Date Description
1.01 07/06/2016 Initial.
1.02    
1.03    
1.04    
1.05    

© Copyright: Owen Duffy 1995, 2021. All rights reserved. Disclaimer.