Feeding at a current maximum, and three other options

Feeding at a current maximum visited the common practice of designing to feed a multi band dipole with open wire feed at or very near to a current maximum.

I explained that feeding at the current maximum may provide sub-optimal performance on the popular T-match ATU as its losses tend to be worst with low R loads, aggravated by the use of 4:1 baluns for even lower R.

On the other hand, feeding at a voltage maximum might exceed the ATU's voltage capacity, or perhaps be outside of the matching range of the ATU.

Well if neither of these is optimal in all cases, what about half way between. It has been done, the odd eighths wave feed line on an 80m half wave is another of the recipes you will hear.

Lets explore the options of a half wave dipole at 3.6MHz with four different feed line lengths (Wireman 551).

The scenario is:

  • dipole feed point Z is taken to be 50+j0Ω, but note that the R component may vary from 40-80Ω for typical implementations, and X will depend on frequency;
  • T-match ATU loss is calculated with W9CF's T-Network Tuner Simulator using default settings (which are probably appropriate to the popular 300W class T-match ATU);
  • ATU loss in Watts and peak voltage are calculated for 300W input to the ATU.
Feed length (°)RXATU loss (%)ATU loss (dB)ATU loss (W)VoutVc1Vc2
451033876.30.28199676131493
903033-248.00.362413491295162
135105-38612.50.58389561269395
18055.507.10.3521182613612

Above is a table of the impedance (R,X) seen by the ATU, ATU loss and peak output and capacitor voltages for a half wave dipole resonant at 3.6MHz.

Some interesting observations:

  • lowest dissipation occurs at 45°, but 180° isn't much worse;
  • lowest output voltage occurs at 180°, the rest are quite higher, 90° worst;
  • voltages are broadly compatible with the nominal 1000Vrms (1414Vpk) rating or 0.8mm spacing that is typical of this class of ATU;
  • dissipation is probably not within the continuous capacity of any of this class of ATU and temperature rise should be measured before operation at high average power (see A look at internal losses in a typical ATU for an example).

If you are using a voltage balun (or an ATU with internal voltage balun), all options except 180° expose the balun to high differential voltage which typically drives high balun loss. If you MUST use a voltage balun, the current maximum feed (or very near to it) is probably the best option for you.

An ideal 4:1 voltage balun in combination with 180° feed line would deliver a load of 14+j0 to the ATU, and ATU dissipation would be 52W with 300W input. It is unlikely that this type of ATU could sustain average dissipation anywhere near that value.

If you use an effective 1:1 current balun, you are not locked in to any of the options to drive good performance, though 1/8 wave (45°) is significantly better than 3/8 wave (135°) which questions the odd eighth wave recipe mentioned.

(Duffy 2010b) simulated a typical 300W class T-match with switched inductor, calculating the loss at a range of VSWR and a range of ATU locations wrt a voltage maximum.

AtuEfficiency03

The graph above shows that loss is worst at high VSWR and when the ATU is located from about 10° to 100° from a voltage maximum. In Smith chart terms, this represents the outer region of the chart and where R is low, and most of the outer region of the chart where X is negative.

The steps are a result of using a stepped inductor which results in sub-optimal matches for some load conditions.

AtuEfficiency05

Above, losses are worse when an ideal 4:1 balun is interposed.

Locating the ATU at the current maximum (90° on the graph) does not deliver lowest ATU loss, more so in the case using the 4:1 balun.

Comments on the model

The article makes observations about the application of an ATU typical of the 300W class of T-match. The model makes some assumptions about capacitor values (250pF max), component Q, and continuously variable inductor, and that optimum match is found. Some ATUs in this class have smaller capacitors (eg MFJ-949E) which will drive higher voltages in some instances. Stepped inductors may result in sub-optimal values that may result in higher losses and higher voltages (Duffy 2010). Balun loss and transformation are ignored.

T-matches with larger capacitors (as typically found in the nominally 3kW class of ATU) can significantly improve performance (lower losses, lower voltages).

T-match performance is likely to be worse on lower frequencies, and better on higher frequencies, it is the nature of the networks and practical component behaviour.

The model is hypothetical and simple, but it gives some insight into the complex interaction of system components.

 Conclusions

  • Voltage baluns are not a good option for this configuration, 4:1 voltage baluns as found in most ATUs are the worst;
  • popular 300W rated T-match ATUs can probably withstand the voltage encountered in this scenario at any feed line length;
  • popular 300W rated T-match ATUs are unlikely to withstand continuous operation at 300W for any feed line length, but will probably cope with higher average power with the 45°, 90° and 180° options (ie NOT -ve reactance) using a 1:1 current balun.
  • simple rules of thumb don't capture the complexity of the configurations.